\documentclass[10pt,a4paper]{article} % Packages \usepackage{fancyhdr} % For header and footer \usepackage{multicol} % Allows multicols in tables \usepackage{tabularx} % Intelligent column widths \usepackage{tabulary} % Used in header and footer \usepackage{hhline} % Border under tables \usepackage{graphicx} % For images \usepackage{xcolor} % For hex colours %\usepackage[utf8x]{inputenc} % For unicode character support \usepackage[T1]{fontenc} % Without this we get weird character replacements \usepackage{colortbl} % For coloured tables \usepackage{setspace} % For line height \usepackage{lastpage} % Needed for total page number \usepackage{seqsplit} % Splits long words. %\usepackage{opensans} % Can't make this work so far. Shame. Would be lovely. \usepackage[normalem]{ulem} % For underlining links % Most of the following are not required for the majority % of cheat sheets but are needed for some symbol support. \usepackage{amsmath} % Symbols \usepackage{MnSymbol} % Symbols \usepackage{wasysym} % Symbols %\usepackage[english,german,french,spanish,italian]{babel} % Languages % Document Info \author{jswans33} \pdfinfo{ /Title (imc-code-checklist-2009-2012.pdf) /Creator (Cheatography) /Author (jswans33) /Subject (IMC CODE CHECKLIST 2009/2012 Cheat Sheet) } % Lengths and widths \addtolength{\textwidth}{6cm} \addtolength{\textheight}{-1cm} \addtolength{\hoffset}{-3cm} \addtolength{\voffset}{-2cm} \setlength{\tabcolsep}{0.2cm} % Space between columns \setlength{\headsep}{-12pt} % Reduce space between header and content \setlength{\headheight}{85pt} % If less, LaTeX automatically increases it \renewcommand{\footrulewidth}{0pt} % Remove footer line \renewcommand{\headrulewidth}{0pt} % Remove header line \renewcommand{\seqinsert}{\ifmmode\allowbreak\else\-\fi} % Hyphens in seqsplit % This two commands together give roughly % the right line height in the tables \renewcommand{\arraystretch}{1.3} \onehalfspacing % Commands \newcommand{\SetRowColor}[1]{\noalign{\gdef\RowColorName{#1}}\rowcolor{\RowColorName}} % Shortcut for row colour \newcommand{\mymulticolumn}[3]{\multicolumn{#1}{>{\columncolor{\RowColorName}}#2}{#3}} % For coloured multi-cols \newcolumntype{x}[1]{>{\raggedright}p{#1}} % New column types for ragged-right paragraph columns \newcommand{\tn}{\tabularnewline} % Required as custom column type in use % Font and Colours \definecolor{HeadBackground}{HTML}{333333} \definecolor{FootBackground}{HTML}{666666} \definecolor{TextColor}{HTML}{333333} \definecolor{DarkBackground}{HTML}{342CA3} \definecolor{LightBackground}{HTML}{F2F1F9} \renewcommand{\familydefault}{\sfdefault} \color{TextColor} % Header and Footer \pagestyle{fancy} \fancyhead{} % Set header to blank \fancyfoot{} % Set footer to blank \fancyhead[L]{ \noindent \begin{multicols}{3} \begin{tabulary}{5.8cm}{C} \SetRowColor{DarkBackground} \vspace{-7pt} {\parbox{\dimexpr\textwidth-2\fboxsep\relax}{\noindent \hspace*{-6pt}\includegraphics[width=5.8cm]{/web/www.cheatography.com/public/images/cheatography_logo.pdf}} } \end{tabulary} \columnbreak \begin{tabulary}{11cm}{L} \vspace{-2pt}\large{\bf{\textcolor{DarkBackground}{\textrm{IMC CODE CHECKLIST 2009/2012 Cheat Sheet}}}} \\ \normalsize{by \textcolor{DarkBackground}{jswans33} via \textcolor{DarkBackground}{\uline{cheatography.com/29703/cs/8767/}}} \end{tabulary} \end{multicols}} \fancyfoot[L]{ \footnotesize \noindent \begin{multicols}{3} \begin{tabulary}{5.8cm}{LL} \SetRowColor{FootBackground} \mymulticolumn{2}{p{5.377cm}}{\bf\textcolor{white}{Cheatographer}} \\ \vspace{-2pt}jswans33 \\ \uline{cheatography.com/jswans33} \\ \end{tabulary} \vfill \columnbreak \begin{tabulary}{5.8cm}{L} \SetRowColor{FootBackground} \mymulticolumn{1}{p{5.377cm}}{\bf\textcolor{white}{Cheat Sheet}} \\ \vspace{-2pt}Published 3rd August, 2016.\\ Updated 4th August, 2016.\\ Page {\thepage} of \pageref{LastPage}. \end{tabulary} \vfill \columnbreak \begin{tabulary}{5.8cm}{L} \SetRowColor{FootBackground} \mymulticolumn{1}{p{5.377cm}}{\bf\textcolor{white}{Sponsor}} \\ \SetRowColor{white} \vspace{-5pt} %\includegraphics[width=48px,height=48px]{dave.jpeg} Measure your website readability!\\ www.readability-score.com \end{tabulary} \end{multicols}} \begin{document} \raggedright \raggedcolumns % Set font size to small. Switch to any value % from this page to resize cheat sheet text: % www.emerson.emory.edu/services/latex/latex_169.html \footnotesize % Small font. \begin{multicols*}{3} \begin{tabularx}{5.377cm}{x{2.4885 cm} x{2.4885 cm} } \SetRowColor{DarkBackground} \mymulticolumn{2}{x{5.377cm}}{\bf\textcolor{white}{INTAKE, EXHAUST \& RETURN LOCATIONS}} \tn % Row 0 \SetRowColor{LightBackground} \mymulticolumn{2}{x{5.377cm}}{{\bf{GENERAL INTAKE}}} \tn % Row Count 1 (+ 1) % Row 1 \SetRowColor{white} 10' from property line & 2009 IMC 401.4(1) \tn % Row Count 3 (+ 2) % Row 2 \SetRowColor{LightBackground} 10' from center line of public way & 2009 IMC 401.4(1) \tn % Row Count 6 (+ 3) % Row 3 \SetRowColor{white} 10' from Xcel transformer & Xcel Blue book. \tn % Row Count 8 (+ 2) % Row 4 \SetRowColor{LightBackground} 10' from building environmental exhaust & 2009 IMC 501.2.1(3) \tn % Row Count 11 (+ 3) % Row 5 \SetRowColor{white} 10' from plumbing vents or 3' below if \textless{}10' & 2009 IMC 401.4(3) \tn % Row Count 14 (+ 3) % Row 6 \SetRowColor{LightBackground} \mymulticolumn{2}{x{5.377cm}}{{\bf{GENERAL EXHAUST}}} \tn % Row Count 15 (+ 1) % Row 7 \SetRowColor{white} 3' from property lines, openigs into buildings & 2009 IMC 501.2.1(3) \tn % Row Count 18 (+ 3) % Row 8 \SetRowColor{LightBackground} 10' from mechanical air inlets & 2009 IMC 501.2.1(3) \tn % Row Count 20 (+ 2) % Row 9 \SetRowColor{white} {\bf{Type I Commercial Hood Exhaust}} & See figure 506.3.10, 10.1(1) and 10.1(2) for summary \tn % Row Count 23 (+ 3) % Row 10 \SetRowColor{LightBackground} {\bf{Type II Commercial Hood}} & 2009 IMC 506.4.2 \& 501.2.1(3) Environmental Air. \tn % Row Count 26 (+ 3) \hhline{>{\arrayrulecolor{DarkBackground}}--} \end{tabularx} \par\addvspace{1.3em} \begin{tabularx}{5.377cm}{x{2.9862 cm} x{1.9908 cm} } \SetRowColor{DarkBackground} \mymulticolumn{2}{x{5.377cm}}{\bf\textcolor{white}{Return Air Prohibited Sources}} \tn % Row 0 \SetRowColor{LightBackground} Machinery eqmt rm & 2009 IMC 918.6(3) \tn % Row Count 2 (+ 2) % Row 1 \SetRowColor{white} Kitchen & 2009 IMC 918.6(5) \tn % Row Count 4 (+ 2) % Row 2 \SetRowColor{LightBackground} Exception: \textgreater{} than 10' from cooking appl. & Exception 2009 IMC 918.6(5) \tn % Row Count 6 (+ 2) % Row 3 \SetRowColor{white} Closet, bathroom, garage, boiler/furnace room, unconditioned attic/crawlspace & 2009 IMC 918.6(5) \tn % Row Count 10 (+ 4) \hhline{>{\arrayrulecolor{DarkBackground}}--} \end{tabularx} \par\addvspace{1.3em} \begin{tabularx}{5.377cm}{x{2.4885 cm} x{2.4885 cm} } \SetRowColor{DarkBackground} \mymulticolumn{2}{x{5.377cm}}{\bf\textcolor{white}{Through Penetrations of Rated Assemblies}} \tn % Row 0 \SetRowColor{LightBackground} \mymulticolumn{2}{x{5.377cm}}{Not required - If not required then must comply with IBC 713.2 through 713.3.3} \tn % Row Count 2 (+ 2) % Row 1 \SetRowColor{white} Required Ratings of Fire Dampers & See 2009 IBC Table 716.3.2.1 \tn % Row Count 4 (+ 2) % Row 2 \SetRowColor{LightBackground} {\bf{Fire Walls}} fire damper required & 2009 IBC 716.5.1 \tn % Row Count 6 (+ 2) % Row 3 \SetRowColor{white} Smoke damper required only serves horizontal exit & 2009 IBC 716.5.1.1 \tn % Row Count 9 (+ 3) % Row 4 \SetRowColor{LightBackground} {\bf{Fire Barriers}} & 2009 IBC 716.5.2 \tn % Row Count 10 (+ 1) % Row 5 \SetRowColor{white} \mymulticolumn{2}{x{5.377cm}}{Fire Damper Required} \tn % Row Count 11 (+ 1) % Row 6 \SetRowColor{LightBackground} Exception - Not required if all below apply: & building sprinklered, wall rating \textless{}1hr, Not grp H, 26ga duct, ducted sa,ra \tn % Row Count 15 (+ 4) % Row 7 \SetRowColor{white} Smoke damper required only if fire wall serves horizontal exit & 2009 IBC 716.5.2.1 \tn % Row Count 19 (+ 4) % Row 8 \SetRowColor{LightBackground} {\bf{Shaft Enclosures}} & 2009 IBC 716.5.3 \tn % Row Count 20 (+ 1) % Row 9 \SetRowColor{white} Fire/Smoke Damper required at all penetrations & 2009 IBC 716.5.3 \tn % Row Count 23 (+ 3) % Row 10 \SetRowColor{LightBackground} \mymulticolumn{2}{x{5.377cm}}{{\bf{Fire Partitions}}} \tn % Row Count 24 (+ 1) % Row 11 \SetRowColor{white} Fire Damper Required & 2009 IBC 716.5.4 \tn % Row Count 25 (+ 1) % Row 12 \SetRowColor{LightBackground} Exception - Not required if all below apply: & Bldg fully sprinkered, fire caulked per 713 \tn % Row Count 28 (+ 3) % Row 13 \SetRowColor{white} \mymulticolumn{2}{x{5.377cm}}{{\bf{ Corridors}}} \tn % Row Count 29 (+ 1) % Row 14 \SetRowColor{LightBackground} Smoke damper required. & 2009 IBC 716.5.4.1 \tn % Row Count 31 (+ 2) \end{tabularx} \par\addvspace{1.3em} \vfill \columnbreak \begin{tabularx}{5.377cm}{x{2.4885 cm} x{2.4885 cm} } \SetRowColor{DarkBackground} \mymulticolumn{2}{x{5.377cm}}{\bf\textcolor{white}{Through Penetrations of Rated Assemblies (cont)}} \tn % Row 15 \SetRowColor{LightBackground} Exception - Not required if all below apply: & No openings in corridor, duct \textgreater{}.019 \tn % Row Count 3 (+ 3) \hhline{>{\arrayrulecolor{DarkBackground}}--} \end{tabularx} \par\addvspace{1.3em} \begin{tabularx}{5.377cm}{x{2.4885 cm} x{2.4885 cm} } \SetRowColor{DarkBackground} \mymulticolumn{2}{x{5.377cm}}{\bf\textcolor{white}{Locate Equipment - Equip on roof.}} \tn % Row 0 \SetRowColor{LightBackground} Show Working Space around all HVAC equipment, panels and etc on plans with hatched area. & 2009 IMC 306.1 \& Manuf. Installation instructions. \tn % Row Count 5 (+ 5) % Row 1 \SetRowColor{white} Permanent ladder required if roof over 16'. & 2009 IMC 306.5 \tn % Row Count 8 (+ 3) % Row 2 \SetRowColor{LightBackground} Level walking surface if roof pitch is over 4/12. & 2009 IMC 306.5 \tn % Row Count 11 (+ 3) % Row 3 \SetRowColor{white} Guard rails req'd if equip \textless{} 10' from edge of roof or 30" drop in elevation. Note this applies to RTU, Fans, roof hatches. Extend 42" high guard, 30" past equipment. Prevent 21" dia sphere. & 2009 IMC 304.11 \tn % Row Count 21 (+ 10) % Row 4 \SetRowColor{LightBackground} Maintenance recptacle, GFI, Same roof level and within 25' of equipment. & 2009 IMC 306.5.2 in accordance with 2011 NEC 210.8(B)(3) \& 210.63 \tn % Row Count 25 (+ 4) % Row 5 \SetRowColor{white} Maintenance platforms req'd if slope of roof is \textgreater{}3/12. If platform is over 30" above roof, a guard rail is required. & 2009 IMC 306.5.1 \tn % Row Count 31 (+ 6) \hhline{>{\arrayrulecolor{DarkBackground}}--} \end{tabularx} \par\addvspace{1.3em} \begin{tabularx}{5.377cm}{x{3.68298 cm} x{1.29402 cm} } \SetRowColor{DarkBackground} \mymulticolumn{2}{x{5.377cm}}{\bf\textcolor{white}{Locate Equipment - Indoor Equip.}} \tn % Row 0 \SetRowColor{LightBackground} Atmospheric vented appliance shall not be in:bedroom, bathroom, toilet room, storage (except sealed combustion) & 2009 IMC 303.3 \tn % Row Count 4 (+ 4) % Row 1 \SetRowColor{white} Appliance in Public garages suspended from the ceiling where vehicles can pass under shall be min 8' or 1' higher than the vehicle entry door, which ever is greater. & 2009 IMC 304.6 \tn % Row Count 10 (+ 6) % Row 2 \SetRowColor{LightBackground} Appliance in Private garages suspended from the ceiling where vehicles can pass under shall be min 6' or 1' higher than the vehicle entry door, which ever is greater. & 2009 IMC 304.7 \tn % Row Count 16 (+ 6) % Row 3 \SetRowColor{white} Room Access Doors - 36" wide X 80" tall. & 2009 IMC 306.2 \tn % Row Count 18 (+ 2) \hhline{>{\arrayrulecolor{DarkBackground}}--} \end{tabularx} \par\addvspace{1.3em} % That's all folks \end{multicols*} \end{document}