Most Common Errors in Leak Testing

This is a draft cheat sheet. It is a work in progress and is not finished yet.

Introd­uction

The smallest leak in a component or sub-as­sembly can compromise a product’s perfor­mance and ultimately your company’s reputa­tion. Product integrity is important. Giving customers a quality product that they can trust for reliab­ility and safety positively impacts a company’s bottom line.

Each year manufa­cturers conduct more than a billion leak tests on critical compon­ents, but there are a number of factors in that process that can hamper successful outcomes. The top 10 mistakes that can hinder successful product leak testing are:

1. USING THE WRONG LEAK-D­ETE­CTION METHOD

Using the bubble test method often produces the wrong results. If the tester does not see any bubbles, then it is assumed there is no leak. The tester believes what he does not see and is satisfied.

Determ­ining whether a leak test or leak detection method for a particular applic­ation is suitable is its leak rate. Unfort­unately this simple rule is often violated. For example, plastic parts are tested using the pressure decay method without consid­ering their deform­ability and changes in volume due to compressed air. Also consider that the leak rate of an integral leak test and subsequent leak detection have to work together. Sometimes the integral leak test is carried out in a helium chamber, but the subsequent locali­zation of leaks is carried out using the bubble test method instead of using a more precise sniffer leak detection method with tracer gas.

2. Testing at Wrong Point in Time In Prod Process

TESTING AT THE WRONG POINT IN TIME IN THE PRODUCTION PROCESS

It is important to think twice when selecting the best point in the production process to perform a leak test. It often makes sense to test individual subcom­ponents for leaks prior to assembly. It is a good idea, for example, to check the tightness of a transm­ission case before the transm­ission is assembled. If the housing fails in the final test and must be rejected, the work of assembling the transm­ission will be lost.

3. TESTING A CONTAM­INATED PART

For virtually all test methods the following should apply: Leak tests always should take place on new, unused test pieces. If a component already has been in operation or has been filled with oil or water, there is a risk that small leaks already may have been clogged.

On castings, sometimes cuttin­g-oil residues remain after the machining process. Before a leak test takes place, the test piece must first be cleaned. After cleaning, the part must then be dried again, which also insures that the cleaning fluid does not clog potential leaks in the short term.
 

4. IGNORING TEMPER­ATURE CHANGES

Temper­ature fluctu­ations represent a serious problem, especially for integral leak tests using pressure decay or differ­ential pressure measur­ement. Even small changes in temper­ature can change the measurable leak rate by several orders of magnitude. The size of a leak also is influenced by increases in temper­ature and the expansion behavior of the material to be tested. In an exhaust gas cooler, in some cases, leaks only occur when the component has reached its typical operating temper­ature. As a result, some manufa­cturers carry out these types of tests in climatic chambers.

5. FLUCTU­ATING TEST PRESSURES

To be able to determine leak rates reliably and reprod­ucibly, it is critical, even when using tracer gas methods, to ensure that the test piece is filled at the same constant pressure. Automated tracer gas filling systems guarantee this. But be careful. In some cases, correctly filling test pieces is only possible after a prior evacua­tion. Heat exchangers usually consist of long, snakelike tube systems. If tracer gas is filled here, it can increase the pressure in the test piece. It is only after a previous evacuation that you can ensure that the tracer gas reaches every possible leak. In addition, especially with the helium tracer gas test, the concen­tration of the tracer gas may be reduced to save on testing costs. Some tests are performed with a helium content of only 1 percen­t—which means that the proper distri­bution of the tracer gas is even more important.

6. FILLING WITH A TEST GAS W/O PREVIOUS EVACUATION

For proper leak testing it is absolutely mandatory to evacuate the test part before filling it with tracer gas. This is partic­ularly important for long and narrow geomet­ries. If you do not evacuate before filling, the air in the test part will simply be pushed to the end of the geometry, and no tracer gas will get to that area. That means that potential leaks will only release the trapped air, which will not be detected by your tracer gas leak detector.

Evacuation also is especially important if you fill the part to be tested with low pressures of tracer gas because the trapped air will dilute the tracer gas as it fills the piece. For example: If the part is filled with air at atmosp­heric pressure and you add one atmosphere of tracer gas, the tracer gas concen­tration in the part is only 50 percent. If you add two atmosp­heres of tracer gas, the concen­tration of tracer gas will be 66 percent.

Leaks

7. NOT KNOWING WHAT YOU ARE TESTING

Using a reprod­ucible measur­ement method as an integral leak test, rather than relying on the mere perception of a human tester is a big step in the right direction. It is important to know what you are actually measuring and which test medium is being used. Occasi­onally leak rates are specified for air, but helium has a slightly higher dynamic viscosity than air. If the leak rate is specified for air, but helium is being used, proper conversion data must be used to provide a more precise leak rate.

If you want to measure the leak rate in grams per year of an air condit­ioning unit with an integral leak test (escaping mass per year) keep in mind that the helium measuring instrument used for the test may, under certain circum­sta­nces, indicate a volume flow of helium in mbar·l/s. There are devices that perform an automatic conver­sion. The exact conversion factors of these units result from the different molecular weights of the refrig­erant.

If, for cost reasons, testing is done with diluted helium mixtures, the helium concen­tra­tions that can be measured are different. This must be taken into account when interp­reting the leak rate results. Moreover, tightness requir­ements always apply to a specific operating pressure. The pressure that is used for the test often deviates. It may be higher or lower than the later operating pressure of the test piece, which also makes a proper conversion of the leak rate necessary.

It also would be a serious mistake to equate a leak rate with a concen­tration of gas that is indicated on some instru­ments as parts per million (ppm). The concen­tration is a snapshot; it only indicates how many particles are in a given space at a given moment. The leak rate indicates, however, the size of the volume flow through a leak.

8. UNDERE­STI­MATING STRINGER LEAKS & GROSS LEAKS

Stringer leaks consisting of capill­ary­-like corridors can seriously affect airbag manufa­ctu­rers. It is important to consider how long it takes for helium tracer gas to distribute in order to emerge from stringer leaks. If you work with very short times between filling and testing, it may be difficult or even impossible to identify stringer leaks. Another example: Even on cable feed-t­hroughs leak channels could be several centim­eters in length. It may take several minutes for the tracer gas to leak through.

The opposite of a stringer leak is a gross leak. In a gross leak the helium escapes from the test piece before the actual test interval. In effect, you evacuate the vacuum test chamber and the helium from the test piece at the same time. Sometimes a simple pressure decay test is integrated into the tracer gas system to identify any gross leaks before filling the test piece with helium.

Leak Types

9. NEGLECTING TEST SYSTEM MAINTE­NANCE

If no leak rates are measured on a test station for days or weeks, it could mean one of two things: Either production quality is superb, or the test system is not functi­oning adequa­tely.

Sometimes leaking tracer gas lines can prevent a correct measur­ement in the test chamber. All inter-­connect points, hoses, test piece brackets, etc., must be checked regularly. Sometimes tracer gas systems are incorr­ectly repaired. It’s a mistake, for example, to wrap an inter-­connect point in TeflonTM tape in order to seal the connec­tion. Helium gas will always escape through the porous Teflon tape, causing accuracy and cost problems.

Sometimes, errors in a test setup can be identified by regularly checking the accuracy of the system by using a reference leak that, due to its defined size, is always the same leak rate. If this leak rate is not determined during the test, the system has inaccu­racies. It is best to opt for a test leak in the form of a glass capillary.
For less demanding test leaks, metal is squeezed to a narrow point. These test leaks will vary greatly in leak rate, depending on temper­ature and pressu­re—­glass capill­aries are therefore better for this purpose. A regular check of the system with a calibr­ation leak also can prevent other very fundam­ental problems. For example, testers may have mistakenly connected an oxygen bottle instead of a helium bottle to their system

10. DOING THINGS YOURSELF

When it comes to industrial leak testing and leak detection, it is important to consult with experts and get advice.

It is critically important to choose the approp­riate test method for a specific applic­ation, to configure the system correctly and to make the review process as foolproof and reliable as possible — certainly not a trivial task.

Again, seek profes­sional support. If you want to ensure the quality of your production and avoid costly product recalls, it is not enough to simply say, “yes, we do check someth­ing.” A negative test is no guarantee that a test piece actually meets the requir­ements set. You can only have this guarantee if your test methods and processes work reliably.

The challenge is to do the right measur­ement and in the right way, every day and at every level.